Core Software Operation
ADDvantage-32 PLUS ● AC to DC Power Converter
3-25
A***:DIF FOOTAGE =
(1, 2, or 4 EDGES/PULSE)(PULSES FREQ IN1)(X***:COUNT 1 CAL)
- (1, 2, or 4 EDGES/PULSE)(PULSES FREQ IN2)(X***:COUNT 2 CAL)
The above equation is modified every one million counts to prevent counter
overflows. This will cause a small floating point error at this event.
When Y***:DIF - CTR RST is high, the differential footage counter is reset.
When Y***:DIF - CTR HLD is high, the differential footage counter is held.
3.12 HARDWARE CONFIGURATION AND DIAGNOSTIC PARAMETERS
X*** Parameters Y*** Parameters A*** Parameters D*** Parameters
Y***:DRIVE P/N A***:LINE VOLTS D***:REV LOCKOUT
X***:ANLG FSCALE Y***:BRG SELFTST A***:LINE FREQ D***:LINE IMBAL
Y***:4Q OPERATE D***:ABC ROTATE
Y***:LINK BAUD D***:PHA LOSS PT
Y***:ANLG DISPLY D***:PHB LOSS PT
D***:PHC LOSS PT
D***:LOW FREQ PT
D***:HI FREQ PT
D***:SCR ENABLE
Hardware configuration parameters are used to set up fundamental operations of the
ADDvantage-32 PLUS. Refer to Appendix C for an explanation of these parameter
functions.
3.13 USER FAULT INPUTS
Y*** Parameters
Y***:USR FAULT 1
Y***:USR FAULT 2
Y***:USR FAULT 3
Y***:USR FAULT 4
Y***:USR FAULT 5
Y***:USR FAULT 6
Y***:USR FAULT 7
Y***:USR FAULT 8
User fault inputs allow the user to enable fault conditions beyond those generated
internally by the ADDvantage-32 PLUS. When the fault condition occurs, the